MODEL | CAPACITY(m3/h) | HEAD (m) | POWER (kw) | CALIBRE (mm) | PUMP MATERIAL | REMARK |
SB-1 | 7.8 | 7.5 | 1.1 | 50/25 | Stainless steel 304 | Impeller/Outlet: plastic |
SB-1-2 | 7.8 | 7.5 | 1.1 | 50/25 | Stainless steel 304 | all stainless steel |
SB-1-1 | 6 | 7 | 0.88 | 50/25 | Stainless steel 304 | Impeller/Outlet: plastic |
SB-1-3 | 6 | 7 | 0.88 | 50/25 | Stainless steel 304 | all stainless steel |
SB-7 | 6 | 7 | 0.55 | 41/25 | Stainless steel 304 | Impeller/Outlet: plastic |
SB-6 | 6 | 7 | 0.55 | 41/25 | Stainless steel 304 | all stainless steel |
SB-3 | 9 | 10 | 0.88 | 50/25 | Stainless steel 304 | Ex-proof motor |
SB-3-1 | 9 | 10 | 0.88 | 50/26 | Stainless steel 304 | Ex-proof motor |
SB-2 | 7.8 | 7.5 | 1.1 | 50/27 | Aluminium alloy | Impeller/Outlet: plastic |
SB-4 | 9 | 10 | 0.88 | 50/28 | Aluminium alloy | Ex-proof motor |
SB-2-1 | 6 | 7 | 0.88 | 50/29 | Aluminium alloy | Impeller/Outlet: plastic |
SB-8 | 6 | 7 | 0.55 | 41/25 | Aluminium alloy | Impeller/Outlet: plastic |
SB-3RPP-50 | 6 | 10 | 0.88 | 50/25 | PP | Ex-proof motor |
JK-3B | 2.4 | 0~3 | 0.12 | 55/20 | Aluminium alloy |
|
JK-3BG | 2.4~3 | 0~6 | 0.18 | 55/20 | Aluminium alloy |
|
JK-3BP | 2.4 | 0~3 | 0.12 | 55/20 | Stainless steel 304 |
|
JK-3BPG | 2.4-3 | 0~6 | 0.18 | 55/20 | Stainless steel 304 |
|
YBYB-40 | 2.4 | 0~3 | 0.12 | 55/20 | Aluminium alloy | Ex-proof motor |
YBYB-40G | 2.4~3 | 0~6 | 0.18 | 55/20 | Aluminium alloy | Ex-proof motor |
YBYB-40P | 2.4 | 0~3 | 0.12 | 55/20 | Stainless steel 304 | Ex-proof motor |
YBYB-40PG | 2.4-3 | 0~6 | 0.18 | 55/20 | Stainless steel 304 | Ex-proof motor |
SB oil drum pump instructions for use:
1, brand-new or long-term shelved oil drum pump use and maintenance, after opening the box with a 500-volt megohmmeter to measure the insulation resistance between all electrically charged parts and metal parts that may be touched, close to the operating temperature should not be less than 7 megohms.
2, pumping pump before use, must check whether the terminals are firm, grounding wire must be reliable and firm.
3、Check whether the power supply voltage of portable oil drum pump is in line with the rated voltage, and it can't be used on the power supply which is more than or less than 10% of the rated voltage.
4, the use of electric oil pump, do not have damage to the wire, to avoid water, oil into the motor, switch, electrical parts.
5、Electric pumping is prohibited to work under the condition of containing flammable and corrosive gases to ensure the safety of production and the normal work of the electrical components.
6, the use of pumping pumps found in the abnormal noise, should be immediately shut down, check the cause, until managed to eliminate before continuing to use.
7, the oil drum pump should not be idle, the use of liquid suction is completed immediately stop the pump, because the pump motor no-load speed of up to 10,000 rpm or so, otherwise it will wear out, universal joint impeller, serious damage to the pump tube.
8, oil drum pump brush replacement: brush wear to can not be used should be replaced immediately, otherwise it will damage the commutator, serious motor will be burned.
9, oil drum pumps should be checked regularly, not generally at least three months to check once a month, often use should be overhauled once a month, overhaul should be completely disassembled to eliminate the internal accumulation of dust, oil. If there is too much carbon on the commutator, alcohol can be used to scrub the surface of the commutator. If there are damaged parts, the same parts should be replaced.
10, oil drum pump when not in use, please place in a dry, clean environment without corrosive gases.
SB Safety Instructions for Drum Pumps:
1, in addition to complying with the instructions outside the strict GB3883. 1-83 ‘hand-held power tools for the safe management of the use, inspection, maintenance of technical regulations’ of the relevant provisions.
2, voltage range rated value ± 10% can be used.
3, avoid electric level and water, oil in the installation of electric level of the place, all the pump, do not damage the electric level, and avoid oil, water and motor switch and other electrical parts of the contact.
4, in order to prevent sudden start, the switch should be in the ‘off’ (i.e., pressed in) state before the power supply is turned on.
5, do not abuse the power cord, the power cord shall not be arbitrarily long or switch. Can not pull the power cord rubbed, cut and rolled and other phenomena.
6, oil drum pump for the explosion-proof type, in the replacement of brushes or maintenance should pay special attention to the explosion-proof parts of the explosion-proof surface can not make the damage to pull hair. In the maintenance or replacement of brushes should open the motor will be inside the cavity carbon powder, oil corrosion and other cleaning.
7, the correct use of the hand, electric pumping pump power cord without a plug at one end, by the user's own choice of the appropriate plug, there are two sides of the three knife point of special attention:
A, oil drum pumps such as explosive and flammable sound with plugs and sockets must comply with the explosion-proof regulations of the plug and socket, set up away from the explosive and flammable site of the normal site, the available 220V5A three-pronged plug, which is a long foot for the grounding foot.
B, oil drum pump regardless of what plug should be reliably grounded, the yellow and green core wire at one end of the power cord for the grounding wire, when properly connected, should also check the pump metal casing and contact between the foot is electrically connected to the foot, the resistance should not be greater than 1 ohm.
8, oil drum pump prohibited places: in special environments such as wet, wind and snow and corrosive gases can not be used.
SB Tank Pump Repair and Maintenance:
1, often add grease, electric pump for high-speed operation, grease is easy to volatilise, it must make the bearing at the lubrication can be kept clean, and pay attention to add change.
2, oil drum pump frequent inspection and maintenance, portable oil drum pump should be frequently inspected, maintenance, must check the power cord: internal wiring, plugs, switches are good, insulation resistance is normal, the brush tail seat is loose, commutator and brush contact is good, armature winding level expansion stator winding is a moderate disconnection phenomenon, bearings and rotating parts whether the damage and so on.
3, save every part and exchange the same parts, in the dismantling and inspection of electric pumping pump, should save every part, pay special attention to the explosion-proof parts of the explosion-proof surface can not make its damage to pull hair, including insulating gaskets and casing, if damaged, must be replaced with new parts of the same, shall not be used less than the performance of the raw material of the substitute material or original specifications of the parts do not match the assembly of all parts should be installed according to the original position, can not be missed. When assembling, all the parts should be installed according to the original position and should not be omitted.
4, oil drum pumps pay attention to insulation resistance, long-term shelved or in a humid environment used in electric pumping pumps, before use must be 500 volts megohmmeter to measure the insulation resistance of the windings. If the insulation resistance between the winding and the motor shell is less than 7 megohms, the winding must be dried.
5, pay attention to the preservation of portable oil drum pump should be placed in a dry, clean and no corrosive gases in the environment.